Appendix E: Pipe Charts

Concrete & Clay Conduits

ODOT SPEC ASTM unless noted as AASHTO CLASS SIZE APPLICABLE CONDUIT TYPE MATERIAL
706.01 C 14 1, 2, 3 4" - 36" A, B, C, D, E non-reinforced concrete
706.02 C 655 2, 3, 4, 5 6" - 144" A, B, C, D, E reinforced concrete
706.03 (706.02, 706.04) C 655 (Type A per 706.02)
C 507 (Type B per 706.04)
epoxy per
DOD-P23236A(SH)

2, 3, 4, 5 (706.02)

HE: 1, 2, 3, 4
VE: 2, 3, 4, 5, 6 (706.04)

6" - 144" (706.02)

equiv. round size
HE: 18" - 144"
VE: 36" - 144"

A epoxy coated reinforced concrete
706.04 C 507 HE: 1, 2, 3, 4
VE: 2, 3, 4, 5, 6
equiv. round size
HE: 18" - 144"
VE: 36" - 144"
A, B, C, D, E elliptical reinforced concrete
706.05 (SS940) C 1577 for spans >12', design according to SS940
(14' - 20' spans)
span by rise:
8x4, 5, 6, 7
10x5, 6, 7, 8, 9;
and 12x4, 6, 8, 10 feet
A, B, C precast reinforced concrete box
706.051 C 1504
AASHTO LRFD Bridge Design Specifications, Section 12.14
5' max cover, greater covers contingent upon manufacturer approval 14' - 34' spans

opening rise: 4' - 10' (max.)
A precast reinforced concrete 3-sided flat topped
706.052 C 1504
AASHTO LRFD Bridge Design Specifications, Section 12.14
12' max cover, greater covers contingent upon manufacturer approval

12" min cover
clear span: 12' to 34', 36', 42', 48', 54', 60'

opening rise: 4' - 13' (max.)
A precast reinforced concrete arch sections
706.053 C 1504
AASHTO LRFD Bridge Design Specifications, Section 12.14
12' max cover, greater covers contingent upon manufacturer approval

12" min cover
clear span: 12, 16, 20, 24, 30, 36, 42, 48, 54, 60, 66, 72, 78, & 84 feet.
available in various rises and shapes
A precast reinforced concrete round sections
706.06 (706.01 or 706.02) C 444
C 14 (706.01)
C 655 (706.02)

Type 1 or 2
1, 2, 3 (706.01)
2, 3, 4, 5 (706.02)

4" - 24"; 27" & larger underdrains perforated concrete
706.07 C 412 extra quality 4" - 36" E, underdrains concrete drain tile
706.08 C 700 extra strength
stnd strength
3" - 48" A, B, C, D, E, underdrains vitrified clay
706.09 C 4 extra quality 3 1/2" - 30" E, underdrains clay drain tile

Type 1: circular perforations, Type 2: slotted perforations

Plastic Conduits

ODOT SPEC ASTM unless noted as AASHTO CLASS SIZE APPLICABLE CONDUIT TYPE MATERIAL
707.31 AASHTO M252
Type C and CP
Class 2
corrugated, open wall
annular or helical
4" - 10" underdrains PE (polyethylene)
707.32 AASHTO M294,
Type C
corrugated, open wall
annular
12" - 60" E PE
707.33 AASHTO M294 (M252 for 4" through 10" diameters)
type S, SP, D
Class 1 (unless otherwise specified)

open or closed profile wall

4" - 60"

A, B, C, D, E, F, lining PE
707.34 F714 closed profile wall 10" - 63" (O.D.) A, B, C, lining PE
707.35 F894 open or closed profile wall 18" - 132" A, B, C, lining PE
707.41 F758, PS46 min  solid wall 4" - 8" E, F, underdrains PVC (polyvinyl chloride)
707.42 F949 open profile wall 4" - 48" B,C, D, E, F, underdrains, lining, non-pressure sanitary PVC
707.43 F794 open profile wall 4" - 48" B, C, D, E, lining, non-pressure sanitary PVC
707.45 D3034, SDR35 solid wall 4"- 15" B, C, D, E, F, underdrains, non-pressure sanitary PVC
707.46 D2665 solid wall 1 1/4" - 24" B, C, E, non-pressure sanitary, vent PVC
707.47 D2680 solid wall 8" - 15" B, C, E, non-pressure sanitary ABS (acrylonitrile-butadiene-styrene) and PVC composite
707.48 F679 solid wall 18" - 60" B, C, D, E, non-pressure sanitary PVC
707.51 D2661 solid wall 1 1/4" - 6"
Schedule 40
B, C, E, non-pressure sanitary, vent ABS
707.62 F2736 corrugated, single wall 6" - 30" D PP (polypropylene)
707.65 F2736 (6" - 30")
F2881 (36" - 60", storm only)
corrugated, double wall 6" - 30"
36" - 60" (storm only)
A, B, C, non-pressure sanitary PP
707.69 F2764 triple wall 30" - 60" A, B, C, non-pressure sanitary PP
707.75 ASTM D3262 (non-pressure)
ASTM D 3754 (pressure)
solid wall 8" - 156" A, B, C, lining, sanitary RPMP (glass-fiber-reinforced-polymer mortar pipe)
748.02 AWWA C900
AWWA C905
AWWA C909
or D2241
solid wall 1/8" - 36" B, C, sanitary, water PVC
748.04 ASTM D3517 or AWWA C950
AWWA M45
solid wall 8" - 156" water RPMP
889.38 P2562 closed profile 12" - 120" A, lining steel reinforced thermoplastic ribbed

Type C: corrugated surface inside and outside
Type CP: Type C w/ Class 2 perforation
Type D (closed profile wall): smooth inside and outside wall annularly (circumferentially) or spirally reinforced with ribs
Type S (open profile wall): outer corrugated wall and smooth inner wall
Type SP: Type S with Class 1 or 2 perforation

Class 1: circular perforation
Class 2: slotted perforation
Schedule 40: iron pipe

Steel Conduits

ODOT SPEC ASTM unless noted as AASHTO CLASS SIZE APPLICABLE CONDUIT TYPE MATERIAL
707.01 M 36 1/4" or 1/2" annular (circumferential) or helical 6" - 84" A, D, E, underdrains, lining metallic coated (zinc galvanizing) or aluminum coated steel
707.02 M 36 1" annular (circumferential) or helical 36" - 120" A, D, E, lining metallic coated (zinc galvanizing) or aluminum coated steel
707.03 M 167 2", 5 1/2", or 6" annular (circumferential) 60" - 312" (for 2" corrugations)
240" - 750" (for 5 1/2" corrugations)
245 - 629" (for 6" corrugations)
A, D, lining zinc coated steel structural plate
707.04 (707.01, 707.02) M 36 (707.01, 707.02)
M 245
M 246
1/4" or 1/2"
1"
annular (circumferential) or helical
12" - 120" A, lining polymeric coated over metallic coated steel (zinc galvanizing)
707.05 (707.01) M 36 (707.01)
M 190, Type B or C
1/2" annular (circumferential) or helical 12" - 84" A, F bituminous coated steel w/ paved invert
707.07 (707.02) M 36 (707.02)
M 190, Type B or C
1" annular (circumferential) or helical 36" - 120" A, F bituminous coated steel w/ paved invert
707.11 M 36, Type IR
M 246
7 1/2" c-c rib spacing 18" - 90" B, C, lining polymer coated steel spiral rib pipe
707.12 M 36, Type IR 7 1/2" c-c rib spacing 18" - 120" lining aluminum coated steel spiral rib
707.13 (707.01) M 36 (707.01)
M 190, Type D
1/2" annular (circumferential) or helical 12" - 84" B, C bituminous lined steel
707.14 (707.02) M 36 (707.02)
M 190, Type D
1" annular (circumferential) or helical 36" - 120" B, C bituminous lined steel
707.15 ASTM A 964 2" or 5.5" max 25'-5" span A zinc coated steel box
707.17 M 36, Type IIA 7 1/2" c-c rib spacing 20" - 81" span
16" - 59" rise
  aluminum coated steel
spiral rib pipe arch
707.18 (707.04) M 36, Type IA (707.04)
M 245
M 246
1/4", 1/2", or 1" helical 12" - 120" lining polymeric coated over metallic coated steel (zinc galvanizing) w/ smooth interior lining
707.19 (707.01, 707.02, 707.04) M 36, Type IA (707.01, 707.02)
M 245 (707.04)
M 246 (707.04)
M 274
1/4", 1/2", or 1" helical 12" - 120" lining aluminum coated steel corrugated exterior w/ polymeric coated over metallic coated steel (zinc galvanizing) smooth interior liner
707.20 (707.01, 707.02, 707.04) M 36, Type IA (707.01, 707.02)
M 245 (707.04)
M 246 (707.04)
M 218
1/4", 1/2", or 1" helical 12" - 120" lining metallic coated (zinc galvanizing) steel corrugated exterior w/ polymeric coated over metallic coated steel (zinc galvanizing) smooth interior liner
748.01 ANI/AWWA C151/A21.51
ANSI/AWWA C150/A21.50
ANSI/AWWA C104/A21.4
solid wall 6" - 64" B, C, sanitary, water ductile iron or ductile iron with polyethylene encasement per 748.07
748.06 ASTM A 139, Grade B or ASTM A 53, Grade B (711.02) solid wall 4" - 24+" casing, lining metallic coated steel (zinc galvanizing) or non-metallic coated for boring and jacking

Type I: single circular corrugated sheet
Type IA: outer circular corrugated sheet and inner circular smooth sheet (double wall)
Type IR: single circular outward projecting helical rib sheet (spiral rib)
Type II: Type I reformed into a pipe-arch
Type IIA: Type IA reformed into a pipe-arch
Type IIR: Type IR reformed into a pip-arch
Type III: Type I with perforations

Coating Designation: Type A fully coated, Type B half coated w/ paved invert, Type C fully coated w/ paved invert, Type D fully coated and fully lined

Steel Grades: A, B, C, D, E

Aluminum Conduits

ODOT SPEC ASTM unless noted as AASHTO CLASS SIZE APPLICABLE CONDUIT TYPE MATERIAL
707.21 M 196 1/4", 7/16", 1/2" annular (circumferential) or helical 6" - 72" A, D, E, F, lining, underdrains aluminum alloy
707.22 M 196 1" annular (circumferential) or helical 36" - 120" A, D, E, F, lining aluminum alloy
707.23 M 219 2 1/2" annular (circumferential) 60 - 312" A, D, lining aluminum alloy structural plate
707.24 M 196, Type IR c-c rib spacing of 7 1/2" 18" - 66" B, C, lining aluminum spiral rib
707.25 ASTM B 864
Type 1 or 2,
Class A-D spacing
2 1/2" max 25'-5" span A aluminum box

Type I: single circular corrugated sheet
Type IA: outer circular corrugated sheet and inner circular smooth sheet (double wall)
Type IR: single circular outward projecting helical rib sheet (spiral rib)
Type II: Type I reformed into a pipe-arch
Type IIA: Type IA reformed into a pipe-arch
Type IIR: Type IR reformed into a pipe-arch
Type III: Type I with perforations

Rib Stiffeners: Type 1 or Type 2

Rib Stiffeners spacing Type 1 or 2: Class A 54" c-c, Class B 27" c-c, Clas C 18" c-c, Class D 9" c-c